|
|
||||||||||||||||||||||||||||
|
|
Exhibitors and Supporters for: The AmSECT Pediatric
Perfusion 2009
Meeting
Exhibitors Circulatory Technology MAQUET Cardiovascular
Medtronic, Inc. Somanetics Corporation
Sorin Group
Circulatory Technology Circulatory Technology Inc. 21 Singworth St., Oyster Bay, NY 11771 Tel. 516-624-2424, Email
ytamari@cirtec.com. Visit us at
www.cirtec.com Circulatory Technology Inc is featuring the Better
Bladder, a compliant venous reservoir placed between the patient and the
pump inlet during ECMO or CPS. The Better-Bladder is available with
either heparin or non heparin coating, in 1/4 With a roller pump,
the Better-Bladder: 1. Takes full advantage of the computer controlled
roller pumps allowing pump speed to be controlled as a function of pump
inlet pressure. 2. Allows use of augmented venous drainage to
facilitate venous blood withdrawal. This eliminates the need to place
the bladder on the floor and allows its placement above the pump thereby
reducing tubing length and prime volume. Actively pulling the blood also
allows the use of a smaller diameter cannula (e.g. when percutaneous
cannulation is used) where the additional cannula resistance to flow is
overcome by a slight negative pressure provided by the pump. Using the
Bigger Better-Bladder (BBB38) and assisted venous drainage allows the
replacement of the 1/2 3. Eliminating the bladder placement at floor level: a. Simplifies transporting the patient. b. Makes it easier to reach a bladder that is at eye
level than below knee level. c. Reduces sterility issues of blood ports near the
floor/feet and allows mopping along the ECMO pump. d. Eliminates the need for raising the bed with
blocks, the patient with mattresses, or the need for a special bed. 4. Provides better flow dynamics than the silicone
bladder resulting in lower stasis and clotting. 5. Inlet and outlet tubing made of standard PVC that
does not kink as easily as the tubing coming off the silicone bladder. 6. Requires very little volume change to cause a
change in pressure (i.e. to control pump flow as a function of pump
inlet pressure). The large volume change associated with the silicone
bladder can cause hemodynamic instabilities. When using centrifugal pumps, the
Better-Bladder provides: 1. Compliance between the patient and the pump inlet
that absorbs the very high negative pressure spikes associated with
sudden stoppage of venous flow (e.g. chattering). Reduction in high
negative pressure reduces the damaging force applied at the tip of the
venous cannula. 2. Traps large air bubbles before they reach the
centrifugal pump. Centrifugal pumps act as a blender that chops large
bubbles into microbubbles that are difficult to remove. Trapping air
bubbles reduces microbubbles reaching the patient.
3. Allows non invasive pressure measurement at the
pump inlet. This eliminates the need for a stopcock that, if opened
accidentally, introduces air into the venous line. MAQUET Cardiovascular offers comprehensive support to perfusionists,
interventionalists, cardiac and vascular surgeons and their teams by providing
on- as well as off-pump coronary artery bypass surgery and intra-aortic balloon
pump therapy solutions. As a global leader, MAQUET Cardiovascular has a focus on extracorporeal
circulation and integrates oxygenators, catheters/cannulae, filtration and other
advanced heart-lung machine components to optimize cardiopulmonary perfusion
outcomes. MAQUET also offers additional innovative technologies such as the
Datascope IABP counterpulsation system, the market leading VASOVIEW Endoscopic
Vessel Harvesting system and a full portfolio of HEMASHIELD surgical grafts and
fabrics designed to improve the quality of cardiovascular patient care. Sorin Group is a world leader in the
treatment of cardiovascular diseases. dedicated to providing our customers with a
Total Systems Approach Our Total Systems Approach features: -Low prime systems for improved patient
outcomes -Pre-assembled perfusion packs providing
convenience and consistency -Blood management solutions with tangible
benefits -Technologically advanced perfusion systems -Unparalleled customer, technical and
clinical support -Endoscopic vessel harvesting - radial and
saphenous. Sorin Cardiopulmonary delivers more than
just quality products, we deliver overall confidence. Call us at 800-221-7943 or visit our website at
www.soringroup-usa.com.
Back to Exhibitor/Sponsor Page |
|
||||||||||||||||||||||||||